Online (GMT+8) Email
|
H&C Diesel Generator Manufacturer
400kW diesel generator set

400kW Diesel Generator Set

400 kW Prime / 440 kW Standby — 500 kVA

Available with Cummins and Perkins engines. ISO 8528-5 certified, factory-direct from China since 1983, exporting since 2003.

What Can a 400kW Diesel Generator Power?

400kW diesel generators power heavy commercial and industrial facilities. They are widely used for hospitals, manufacturing plants, commercial buildings, cold storage, and mid-size data centers requiring robust standby or continuous prime power.

Hospitals Manufacturing Plants Commercial Buildings

400kW Diesel Generator — Engine Options

Two engine platforms are available at 400kW. Choose based on your application, budget, and service requirements.

Cummins engine

Cummins 400kW Diesel Generator

Model: R-CC500D5/S · 50Hz (1500 rpm)

GET CUMMINS QUOTE →
Standby Power 440 kW / 550 kVA
Prime Power 400 kW / 500 kVA
Engine Model KTA19-G3A
Alternator Stamford S5L1D-C4 / Leroy-Somer TAL-A473-C
Fuel Consumption 72.5 / 96.7 L/h (@75% / @100%)
Fuel Efficiency 203 g/kW·h (ISO 3046-1)
Sound Level ≤75 dB(A) at 7m
Dimensions (Open / Silent) 3400×1380×2000 / 4830×1930×2200 mm
Weight (Open / Silent) 4500 / 5500 kg
Frequency 50Hz (1500 rpm)

💰 Operating Cost Estimate

75% Load

72.5 L/h

100% Load

96.7 L/h

Operating cost = L/h × local diesel price.
Example at $1.0/L: 75% load ≈ $73/hr.

🛢️ Maintenance Quick Reference

Oil Capacity

50L

SAE 15W-40 CH-4

Coolant Capacity

30.3L

50:50 EG + H₂O

Global service network — ideal for critical standby in data centers and hospitals.

View Cummins Series →

Nearby ratings: Also available: R-DC500D5/S — Prime 400 kW / Standby 440 kW · R-CC525D5/S — Prime 420 kW / Standby 462 kW.

Perkins engine

Perkins 400kW Diesel Generator

Model: R-P500D5/S · 50Hz (1500 rpm)

GET PERKINS QUOTE →
Standby Power 440 kW / 550 kVA
Prime Power 400 kW / 500 kVA
Engine Model 2506C-E15TAG2
Alternator Stamford S5L1D-C4 / Leroy-Somer TAL-A473-C
Fuel Consumption 70.0 / 93.3 L/h (@75% / @100%)
Fuel Efficiency 196 g/kW·h (ISO 3046-1)
Sound Level ≤75 dB(A) at 7m
Dimensions (Open / Silent) 3400×1120×2050 / 5030×1830×2050 mm
Weight (Open / Silent) 2700 / 3150 kg
Frequency 50Hz (1500 rpm)

💰 Operating Cost Estimate

75% Load

70.0 L/h

100% Load

93.3 L/h

Operating cost = L/h × local diesel price.
Example at $1.0/L: 75% load ≈ $70/hr.

🛢️ Maintenance Quick Reference

Oil Capacity

38L

SAE 15W-40 CH-4

Coolant Capacity

41L

50:50 EG + H₂O

Proven low lifecycle cost with worldwide parts availability — strong prime-power reliability.

View Perkins Series →

Nearby ratings: Also available: R-P450D5/S — Prime 360 kW / Standby 396 kW · R-P600D5/S — Prime 480 kW / Standby 528 kW.

400kW Generator — Quick Comparison

All models are rated 400 kW Prime / 440 kW Standby at 50Hz (1500 rpm), each with a Stamford / Leroy-Somer alternator and DSE7320 controller. Key differences below.

Specification Cummins Perkins
Model R-CC500D5/S R-P500D5/S
Engine KTA19-G3A 2506C-E15TAG2
Fuel @75% (L/h) 72.5 70.0
Fuel Efficiency (g/kW·h) 203 196
Dimensions — Open (mm) 3400×1380×2000 3400×1120×2050
Weight — Open / Silent (kg) 4500 / 5500 2700 / 3150
Oil Capacity (L) 50 38
Coolant Capacity (L) 30.3 41

Explore Nearby Power Ratings

← Back to All Power Ratings

Frequently Asked Questions — 400kW Diesel Generator

How much does a 400kW diesel generator cost?+
A 400kW diesel generator is priced by engine platform, configuration and alternator choice. At this rating H&C builds 2 engine platforms (Cummins R-CC500D5/S, Perkins R-P500D5/S), rated 400 kW / 500 kVA prime and 440 kW / 550 kVA standby at 50Hz (1500 rpm). The price moves with the enclosure (open skid, soundproof canopy or containerized), the alternator (Stamford S5L1D-C4 or Leroy-Somer TAL-A473-C for the R-CC500D5/S), the controller and options such as ATS, and with the destination country and freight terms. Send your voltage, frequency and destination country and we will confirm the R-CC500D5/S / R-P500D5/S price within 24 hours.
What is the fuel consumption of a 400kW diesel generator?+
Fuel consumption for a 400kW diesel generator is 70.0-72.5 L/h at 75% load and 93.3-96.7 L/h at 100% load across the 2 platforms: Cummins R-CC500D5/S 72.5 / 96.7 L/h; Perkins R-P500D5/S 70.0 / 93.3 L/h. Measured efficiency is 196-203 g/kW·h per ISO 3046-1, and actual consumption varies about ±5% with ambient conditions, load profile and fuel quality. At a diesel price of $1.0/L, 75% load costs roughly $70-72 per hour.
What can a 400kW diesel generator power?+
A 400kW set powers heavy commercial and industrial facilities: hospitals, manufacturing plants, commercial buildings, cold storage and mid-size data centers. At this rating Cummins and Perkins are available, so the same 440 kW / 550 kVA standby rating can be specified on any of them. Tell us your connected load and the largest motor you need to start and we will confirm whether 400kW or the next rating up fits better.
Which engine brands and configurations are available for a 400kW generator?+
The 400kW rating is available on 2 engine platforms: Cummins R-CC500D5/S (KTA19-G3A, 203 g/kW·h), Perkins R-P500D5/S (2506C-E15TAG2, 196 g/kW·h). Efficiency for the R-CC500D5/S and its alternatives is measured per ISO 3046-1. Units ship as open skid, weatherproof silent canopy or 20ft/40ft container; the silent canopy for the R-CC500D5/S holds ≤75 dB(A) at 7m. All 2 platforms (from the R-CC500D5/S) are built to 50Hz (1500 rpm) as standard, with custom controls and ATS available on request.

Tell us your requirements — we'll recommend the right brand and configuration for your application.

GET 400kW QUOTE →