Mitsubishi Diesel Generator Sets 520–1800kW
Factory-direct Mitsubishi generators 520–1,800kW. R-SM and R-JM series with genuine Mitsubishi Heavy Industries S6R, S12, and S16 engines. ISO 8528 certified. 50Hz. Japanese engineering — proven in extreme environments since 1917.
Why Choose Mitsubishi Diesel Generators?
Mitsubishi Heavy Industries (MHI) engines deliver Japanese precision engineering with a low failure rate — MHI builds its own fuel pump, turbocharger and injectors. The S6R, S12R and S16R engine families are purpose-built for power generation, with an operating range of -30°C to 50°C.
H&C offers both the R-SM (SME) and R-JM (JM) Mitsubishi-powered series — from the S6R2 6-cylinder (520kW) to the S16R2 16-cylinder (1,800kW). JM is built in Japan; SM is built in the China joint venture with a "-C" model suffix — same models and technology. Each genset is paired with a Leroy-Somer or Stamford alternator and Deep Sea 7320 controller, assembled and load-tested at our manufacturing facility in Jiangsu, China.
For sites in the Middle East, Africa, and high-temperature regions, Mitsubishi is engineered for harsh conditions: 10-second start, 100% one-step load acceptance, and 300% momentary overload — specified for data-center designs targeting Uptime Institute Tier III/IV.
Japanese Precision, Low Failure Rate
MHI builds its own fuel pump, turbocharger and injectors, and the engines use a cast-iron block, forged crankshaft and replaceable wet liners.
High-Ambient Performance
-30°C to 50°C — built for Middle East and desert conditions, with high fuel efficiency from precision injection and MHI-matched turbocharging.
Strong Starting
10-second start, 100% one-step load acceptance and 300% momentary overload — specified for data-center designs targeting Uptime Institute Tier III/IV.
Mitsubishi Generator Power Range
R-SM & R-JM series — 21 models covering 520–1,800kW prime power. 50Hz / 400V / 0.8PF. Fuel consumption computed from g/kW·h per ISO 3046-1. R-JM dimension data pending verification — contact us for exact specs. Click Details → for R-SM verified specifications.
| Model | Standby kW / kVA |
Prime kW / kVA |
Engine Model | Fuel L/h @75% / @100% |
View |
|---|---|---|---|---|---|
| R-SM650D5/S | 572 / 715 | 520 / 650 | S6R2-PTA-C | 93.8 / 125.0 | Details → |
| R-JM650D5/S | 572 / 715 | 520 / 650 | S6R2-PTA | 91.0 / 121.3 | Details → |
| R-SM750D5/S | 660 / 825 | 600 / 750 | S6R2-PTAA-C | 108.8 / 145.0 | Details → |
| R-JM750D5/S | 660 / 825 | 600 / 750 | S6R2-PTAA | 105.0 / 140.0 | Details → |
| R-JM800D5/S | 704 / 880 | 640 / 800 | S12A2-PTA | 126.3 / 168.4 | Details → |
| R-JM900D5/S | 800 / 1000 | 720 / 900 | S12A2-PTA2 | 142.1 / 189.4 | Details → |
| R-JM1000D5/S | 880 / 1100 | 800 / 1000 | S12H-PTA | 147.1 / 196.2 | Details → |
| R-SM1250D5/S | 1100 / 1375 | 1000 / 1250 | S12R-PTA-C | 178.6 / 238.1 | Details → |
| R-JM1250D5/S | 1100 / 1375 | 1000 / 1250 | S12R-PTA | 197.3 / 263.1 | Details → |
| R-SM1375D5/S | 1210 / 1512 | 1100 / 1375 | S12R-PTA2-C | 195.4 / 260.6 | Details → |
| R-JM1375D5/S | 1210 / 1512 | 1100 / 1375 | S12R-PTA2 | 217.1 / 289.4 | Details → |
| R-SM1500D5/S | 1320 / 1650 | 1200 / 1500 | S12R-PTAA2-C | 213.2 / 284.3 | Details → |
| R-JM1500D5/S | 1320 / 1650 | 1200 / 1500 | S12R-PTAA2 | 223.9 / 298.6 | Details → |
| R-JM1675D5/S | 1452 / 1815 | 1320 / 1650 | S16R-PTA | 242.8 / 323.7 | Details → |
| R-SM1650D5/S | 1500 / 1875 | 1350 / 1650 | S16R-PTA-C | 244.7 / 326.2 | Details → |
| R-SM1875D5/S | 1650 / 2062 | 1500 / 1875 | S16R-PTA2-C | 269.2 / 358.9 | Details → |
| R-JM1875D5/S | 1650 / 2062 | 1500 / 1875 | S16R-PTA2 | 277.2 / 369.6 | Details → |
| R-SM2000D5/S | 1760 / 2200 | 1600 / 2000 | S16R-PTAA2-C | 285.7 / 381.0 | Details → |
| R-JM2000D5/S | 1760 / 2200 | 1600 / 2000 | S16R-PTAA2 | 294.3 / 392.4 | Details → |
| R-SM2250D5/S | 2000 / 2500 | 1800 / 2250 | S16R2-PTAW-C | 335.9 / 447.9 | Details → |
| R-JM2250D5/S | 1980 / 2475 | 1800 / 2250 | S16R2-PTAW | 335.9 / 447.9 | Details → |
Mitsubishi Generator Specifications by Power Rating
Detailed specs for 4 key Mitsubishi power ratings (R-SM series with verified dimensions). 50Hz. Find every available model in the complete power range table above.
📋 Buying & Service Guides
Plan your purchase and keep your generator running at peak performance with our complete, brand-independent guides.
Diesel Generator Buying Guide → Diesel Generator Maintenance Schedule →Mitsubishi 520kW Diesel Generator
R-SM Series · S6R2 · 50Hz · Model: R-SM650D5/S
| Standby Power | 572 kW / 715 kVA |
| Prime Power | 520 kW / 650 kVA |
| Engine Model | Mitsubishi S6R2-PTA-C |
| Alternator | Stamford S5L1D-F4 / Leroy-Somer TAL-A473-F |
| Fuel Consumption | 93.8 / 125.0 L/h (@75% / @100%) |
| Fuel Efficiency | 202 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 3420×1550×2100 / 5030×1850×2510 mm |
| Weight (Open / Silent) | 4000 / 5000 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-SM750D5/S (600kW) — S6R2-PTAA-C · R-JM650D5/S (520kW) · R-JM750D5/S (600kW) · R-JM800D5/S (640kW) · R-JM900D5/S (720kW). 6 models in this power bracket spanning R-SM and R-JM product lines.
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
93.8 L/h
100% Load
125.0 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$93.8/hr | 100% load costs ~$125.0/hr
🛢️ Maintenance Quick Reference
Oil Capacity
94L
SAE 15W-40 CH-4
Coolant Capacity
55L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Mitsubishi 1000kW Diesel Generator
R-SM Series · S12R · 50Hz · Model: R-SM1250D5/S
| Standby Power | 1,100 kW / 1,375 kVA |
| Prime Power | 1,000 kW / 1,250 kVA |
| Engine Model | Mitsubishi S12R-PTA-C |
| Alternator | Stamford S6L1D-G4 / Leroy-Somer LSA 50.2 M6 |
| Fuel Consumption | 178.6 / 238.1 L/h (@75% / @100%) |
| Fuel Efficiency | 200 g/kW·h (ISO 3046-1) |
| Sound Level | ≤85 dB(A) at 7m (container) |
| Dimensions (Open / Silent) | 4450×1850×2250 / 12192×2435×2896 mm |
| Weight (Open / Silent) | 10000 / 11500 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-SM1375D5/S (1100kW) — S12R-PTA2-C · R-JM1000D5/S (800kW) · R-JM1250D5/S (1000kW) · R-JM1375D5/S (1100kW). 5 models spanning the 800–1,100kW range.
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
178.6 L/h
100% Load
238.1 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$178.6/hr | 100% load costs ~$238.1/hr
🛢️ Maintenance Quick Reference
Oil Capacity
180L
SAE 15W-40 CH-4
Coolant Capacity
150L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Mitsubishi 1,200kW Diesel Generator
R-SM Series · S12R-PTAA2 · 50Hz · Model: R-SM1500D5/S
| Standby Power | 1,320 kW / 1,650 kVA |
| Prime Power | 1,200 kW / 1,500 kVA |
| Engine Model | Mitsubishi S12R-PTAA2-C |
| Alternator | Stamford S7L1D-C4 / Leroy-Somer LSA 50.2 L8 |
| Fuel Consumption | 213.2 / 284.3 L/h (@75% / @100%) |
| Fuel Efficiency | 199 g/kW·h (ISO 3046-1) |
| Sound Level | ≤85 dB(A) at 7m (container) |
| Dimensions (Open / Silent) | 4850×2000×2450 / 12192×2435×2896 mm |
| Weight (Open / Silent) | 10100 / 11600 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-SM1650D5/S (1350kW) — S16R-PTA-C · R-SM1875D5/S (1500kW) — S16R-PTA2-C · R-JM1500D5/S (1200kW) · R-JM1675D5/S (1320kW) · R-JM1875D5/S (1500kW). 6 models from the S12R-PTAA2, S16R, and R-JM families.
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
213.2 L/h
100% Load
284.3 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$213.2/hr | 100% load costs ~$284.3/hr
🛢️ Maintenance Quick Reference
Oil Capacity
180L
SAE 15W-40 CH-4
Coolant Capacity
125L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Mitsubishi 1800kW Diesel Generator
R-SM Series · S16R2 · 50Hz · Model: R-SM2250D5/S
| Standby Power | 2,000 kW / 2,500 kVA |
| Prime Power | 1,800 kW / 2,250 kVA |
| Engine Model | Mitsubishi S16R2-PTAW-C |
| Alternator | Stamford S7L1D-H4 / Leroy-Somer LSA 52.3 L9 |
| Fuel Consumption | 335.9 / 447.9 L/h (@75% / @100%) |
| Fuel Efficiency | 209 g/kW·h (ISO 3046-1) |
| Sound Level | ≤85 dB(A) at 7m (container) |
| Dimensions (Open / Silent) | 6050×2500×3200 / 12192×2435×2896 mm |
| Weight (Open / Silent) | 15000 / 18000 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-SM2000D5/S (1600kW) — S16R-PTAA2-C · R-JM2000D5/S (1600kW) · R-JM2250D5/S (1800kW). The flagship S16R2 is the largest Mitsubishi engine at H&C, delivering 1,800kW prime with mechanical injection for harsh environments.
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
335.9 L/h
100% Load
447.9 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$335.9/hr | 100% load costs ~$447.9/hr
🛢️ Maintenance Quick Reference
Oil Capacity
230L
SAE 15W-40 CH-4
Coolant Capacity
170L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Mitsubishi Generator — Technical Data
Fuel Consumption
Most fuel-efficient · S6R2-PTA @ 520kW (R-JM series)
Actual consumption @75% load (sample)
520kW
1200kW
1800kW
Measured per ISO 3046-1 at 75% load. Actual varies ±5% with ambient conditions and load profile. Mitsubishi mechanical injection engines tolerate fuel quality variations better than common-rail designs — a decisive advantage in regions where fuel sulfur content or cleanliness is uncertain.
Engineering & Configuration
H&C offers the full R-SM and R-JM range from 520kW to 1,800kW. For Middle East, Africa, and tropical climate projects, Mitsubishi is the brand we most frequently recommend — its 50°C ambient rating and mechanical injection eliminate the two most common causes of generator field failure. Contact us for a climate-specific recommendation.
Standards & Compliance
Factory Load Test (ISO 8528)
Stepped load bank test on every unit. Reports available upon request.
Factory Warranty: 12 months / 1,000 hours — full MHI factory warranty. Extended plans available upon request.