Perkins Diesel Generator Sets 7–1800kW
Factory-direct Perkins generators 7–1800kW. R-P series with genuine Perkins 400, 1100, 1200, 1500, 2200, 2500, 2800, and 4000 series engines. ISO 8528 certified. 50Hz. Backed by Perkins' worldwide service network.
Why Choose Perkins Diesel Generators?
Perkins Engines Company Limited, headquartered in Peterborough, UK, is a subsidiary of Caterpillar Inc. with manufacturing facilities in China, India, the USA and the UK — a global footprint that gives buyers with engine-origin restrictions an extra choice. Perkins engines power generator sets from 7kW to 1,800kW.
H&C integrates the complete Perkins R-P series into our generator sets: from the compact 400 Series (7kW) to the industrial 4000 Series (1,800kW). Every genset is paired with a Stamford or Leroy-Somer alternator and Deep Sea / ComAp controller — assembled and load-tested at our manufacturing facility in Jiangsu, China per ISO 8528 standards.
For buyers, Perkins is engineered for low lifetime maintenance: the 2000 Series is built in the same factory as Caterpillar, and engines across families share common components with long service intervals. The 1100 Series uses mechanical injection with a 500-hour service interval — fast on-site servicing, less labour, and less downtime.
Global Manufacturing Footprint
Engines built in China, India, the USA and the UK — an extra choice for buyers whose project requires a specific engine origin.
Proven Reliability
The 2000 Series is built in the same factory as Caterpillar, backed by Perkins’ worldwide after-sales network.
Simple Maintenance, Less Downtime
Single-side service, common components across engine families, and long intervals — the 1100 Series uses mechanical injection with a 500-hour service interval.
Perkins Generator Power Range
R-P series — 38 models covering 7–1800kW prime power. 50Hz / 400V / 0.8PF. Includes fuel consumption data. Click Details → for full specifications and application guidance.
| Model | Standby kW / kVA |
Prime kW / kVA |
Engine Model | Fuel L/h @75% / @100% |
View |
|---|---|---|---|---|---|
| R-P9D5/S | 7 / 9 | 7 / 9 | 403D-11G | 1.6 / 2.1 | Details → |
| R-P13D5/S | 11 / 13 | 10 / 12 | 403D-15G | 2.4 / 3.1 | Details → |
| R-P15D5/S | 13 / 16 | 12 / 15 | 403A-15G2 | 2.7 / 3.5 | Details → |
| R-P20D5/S | 17 / 22 | 16 / 20 | 404D-22G | 3.6 / 4.8 | Details → |
| R-P25D5/S | 22 / 27 | 20 / 25 | 404D-22TG | 4.2 / 5.6 | Details → |
| R-P30D5/S | 26 / 33 | 24 / 30 | 1103A-33G | 5.1 / 6.8 | Details → |
| R-P45D5/S | 39 / 49 | 36 / 45 | 1103A-33TG1 | 6.8 / 9.0 | Details → |
| R-P60D5/S | 52 / 66 | 48 / 60 | 1103A-33TG2 | 9.1 / 12.2 | Details → |
| R-P65D5/S | 57 / 71 | 52 / 65 | 1104A-44TG1 | 9.8 / 13.1 | Details → |
| R-P80D5/S | 70 / 88 | 64 / 80 | 1104A-44TG2 | 11.9 / 15.8 | Details → |
| R-P100D5/S | 88 / 110 | 80 / 100 | 1104C-44TAG2 | 15.3 / 20.4 | Details → |
| R-P135D5/S | 118 / 148 | 108 / 135 | 1106A-70TG1 | 20.1 / 26.7 | Details → |
| R-P150D5/S | 132 / 165 | 120 / 150 | 1106A-70TAG2 | 21.6 / 28.9 | Details → |
| R-P180D5/S | 158 / 198 | 144 / 180 | 1106A-70TAG3 | 26.1 / 34.8 | Details → |
| R-P200D5/S | 176 / 220 | 160 / 200 | 1106A-70TAG4 | 29.0 / 38.7 | Details → |
| R-P200D5/S | 176 / 220 | 160 / 200 | 1206A-E70TTAG1 | 29.6 / 39.4 | Details → |
| R-P230D5/S | 202 / 253 | 184 / 230 | 1206A-E70TTAG2 | 35.0 / 46.7 | Details → |
| R-P250D5/S | 220 / 275 | 200 / 250 | 1206A-E70TTAG3 | 36.8 / 49.0 | Details → |
| R-P300D5/S | 264 / 330 | 240 / 300 | 1506A-E88TAG5 | 42.2 / 56.3 | Details → |
| R-P350D5/S | 308 / 385 | 280 / 350 | 2206C-E13TAG2 | 51.8 / 69.0 | Details → |
| R-P400D5/S | 352 / 440 | 320 / 400 | 2206C-E13TAG3 | 56.6 / 75.4 | Details → |
| R-P450D5/S | 396 / 495 | 360 / 450 | 2506C-E15TAG1 | 66.9 / 89.1 | Details → |
| R-P500D5/S | 440 / 550 | 400 / 500 | 2506C-E15TAG2 | 70.0 / 93.3 | Details → |
| R-P600D5/S | 528 / 660 | 480 / 600 | 2806C-E18TAG1A | 89.6 / 119.4 | Details → |
| R-P650D5/S | 572 / 715 | 520 / 650 | 2806A-E18TAG2 | 95.6 / 127.5 | Details → |
| R-P700D5/S | 616 / 770 | 560 / 700 | 2806A-E18TTAG4 | 108.0 / 144.0 | Details → |
| R-P750D5/S | 660 / 825 | 600 / 750 | 2806A-E18TTAG5 | 113.0 / 150.7 | Details → |
| R-P750D5/S | 660 / 825 | 600 / 750 | 4006-23TAG2A | 115.7 / 154.3 | Details → |
| R-P800D5/S | 704 / 880 | 640 / 800 | 4006-23TAG3A | 115.4 / 153.9 | Details → |
| R-P900D5/S | 792 / 990 | 720 / 900 | 4008TAG1A | 129.9 / 173.1 | Details → |
| R-P1000D5/S | 880 / 1100 | 800 / 1000 | 4008TAG2 | 150.0 / 200.0 | Details → |
| R-P1125D5/S | 990 / 1237 | 900 / 1125 | 4008-30TAG3 | 163.1 / 217.5 | Details → |
| R-P1250D5/S | 1100 / 1375 | 1000 / 1250 | 4012-46TWG2A | 183.0 / 244.0 | Details → |
| R-P1500D5/S | 1320 / 1650 | 1200 / 1500 | 4012-46TAG2A | 220.7 / 294.3 | Details → |
| R-P1650D5/S | 1452 / 1815 | 1320 / 1650 | 4012-46TAG3A | 248.7 / 331.6 | Details → |
| R-P1875D5/S | 1650 / 2062 | 1500 / 1875 | 4016TAG1A | 282.6 / 376.8 | Details → |
| R-P2000D5/S | 1760 / 2200 | 1600 / 2000 | 4016TAG2A | 285.7 / 381.0 | Details → |
| R-P2250D5/S | 1980 / 2500 | 1800 / 2250 | 4016-61TRG3 | 334.3 / 445.7 | Details → |
Perkins Generator Specifications by Power Rating
Detailed specs and application guidance for 8 popular Perkins generator power ratings (10–480kW). Covers genuine Perkins 400, 1100, and 2800 series engines. 50Hz. Find every available model in the complete power range table above.
📋 Buying & Service Guides
Plan your purchase and keep your generator running at peak performance with our complete, brand-independent guides.
Diesel Generator Buying Guide → Diesel Generator Maintenance Schedule →Perkins 10kW Diesel Generator
Perkins 400 Series · 50Hz · Model: R-P13D5/S
| Standby Power | 11 kW / 13.8 kVA |
| Prime Power | 10 kW / 12.5 kVA |
| Engine Model | Perkins 403D-15G |
| Alternator | Stamford S0L1-L1 / Leroy-Somer TAL-A40-C |
| Fuel Consumption | 2.4 / 3.1 L/h (@75% / @100%) |
| Fuel Efficiency | 264 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1160×780×1170 / 1830×750×1090 mm |
| Weight (Open / Silent) | 700 / 1050 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P9D5/S (7kW) · R-P15D5/S (12kW) — 403 family compact engines for light commercial backup
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
2.4 L/h
100% Load
3.1 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$2.4/hr | 100% load costs ~$3.1/hr
🛢️ Maintenance Quick Reference
Oil Capacity
6L
SAE 15W-40 CH-4
Coolant Capacity
5L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 16kW Diesel Generator
Perkins 400 Series · 50Hz · Model: R-P20D5/S
| Standby Power | 17.6 kW / 22 kVA |
| Prime Power | 16 kW / 20 kVA |
| Engine Model | Perkins 404D-22G |
| Alternator | Stamford S0L2-G1 / Leroy-Somer TAL-A40-F |
| Fuel Consumption | 3.6 / 4.8 L/h (@75% / @100%) |
| Fuel Efficiency | 250 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1160×780×1170 / 1830×750×1090 mm |
| Weight (Open / Silent) | 800 / 1120 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P25D5/S (20kW) — 404D-22TG turbocharged variant for higher output
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
3.6 L/h
100% Load
4.8 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$3.6/hr | 100% load costs ~$4.8/hr
🛢️ Maintenance Quick Reference
Oil Capacity
6L
SAE 15W-40 CH-4
Coolant Capacity
6L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 26kW Diesel Generator
Perkins 1100 Series · 50Hz · Model: R-P30D5/S
| Standby Power | 26.4 kW / 33 kVA |
| Prime Power | 24 kW / 30 kVA |
| Engine Model | Perkins 1103A-33G |
| Alternator | Stamford S0L2-P1 / Leroy-Somer TAL-A42-C |
| Fuel Consumption | 5.1 / 6.8 L/h (@75% / @100%) |
| Fuel Efficiency | 237 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1160×780×1170 / 2030×890×1105 mm |
| Weight (Open / Silent) | 840 / 1160 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P45D5/S (36kW) — 1103A-33TG1, the first turbocharged model in the 1100 Series
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
5.1 L/h
100% Load
6.8 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$5.1/hr | 100% load costs ~$6.8/hr
🛢️ Maintenance Quick Reference
Oil Capacity
8L
SAE 15W-40 CH-4
Coolant Capacity
8L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 57kW Diesel Generator
Perkins 1100 Series · 50Hz · Model: R-P65D5/S
| Standby Power | 57.2 kW / 71.5 kVA |
| Prime Power | 52 kW / 65 kVA |
| Engine Model | Perkins 1104A-44TG1 |
| Alternator | Stamford UCI224F / Leroy-Somer TAL-A42-H |
| Fuel Consumption | 9.8 / 13.1 L/h (@75% / @100%) |
| Fuel Efficiency | 212 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1680×825×1230 / 2480×1030×1315 mm |
| Weight (Open / Silent) | 1140 / 1560 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P60D5/S (48kW) — 1103A-33TG2, the final 1103A evolution before the 1104A platform
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
9.8 L/h
100% Load
13.1 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$9.8/hr | 100% load costs ~$13.1/hr
🛢️ Maintenance Quick Reference
Oil Capacity
8L
SAE 15W-40 CH-4
Coolant Capacity
10L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 70kW Diesel Generator
Perkins 1100 Series · 50Hz · Model: R-P80D5/S
| Standby Power | 70.4 kW / 88 kVA |
| Prime Power | 64 kW / 80 kVA |
| Engine Model | Perkins 1104A-44TG2 |
| Alternator | Stamford UCI224G / Leroy-Somer TAL-A44-C |
| Fuel Consumption | 11.9 / 15.9 L/h (@75% / @100%) |
| Fuel Efficiency | 208 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1860×855×1250 / 2580×1030×1500 mm |
| Weight (Open / Silent) | 1150 / 1600 kg |
| Price (Indicative) | Request Quote → |
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
11.9 L/h
100% Load
15.9 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$11.9/hr | 100% load costs ~$15.9/hr
🛢️ Maintenance Quick Reference
Oil Capacity
8L
SAE 15W-40 CH-4
Coolant Capacity
13L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 80kW Diesel Generator
Perkins 1100 Series · 50Hz · Model: R-P100D5/S
| Standby Power | 88 kW / 110 kVA |
| Prime Power | 80 kW / 100 kVA |
| Engine Model | Perkins 1104C-44TAG2 |
| Alternator | Stamford UCI274C / Leroy-Somer TAL-A44-D |
| Fuel Consumption | 15.3 / 20.4 L/h (@75% / @100%) |
| Fuel Efficiency | 214 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1860×855×1250 / 2580×1030×1500 mm |
| Weight (Open / Silent) | 1200 / 1700 kg |
| Price (Indicative) | Request Quote → |
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
15.3 L/h
100% Load
20.4 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$15.3/hr | 100% load costs ~$20.4/hr
🛢️ Maintenance Quick Reference
Oil Capacity
8L
SAE 15W-40 CH-4
Coolant Capacity
13L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 108kW Diesel Generator
Perkins 1100 Series · 50Hz · Model: R-P135D5/S
| Standby Power | 118.8 kW / 148.5 kVA |
| Prime Power | 108 kW / 135 kVA |
| Engine Model | Perkins 1106A-70TG1 |
| Alternator | Stamford UCI274E / Leroy-Somer TAL-A44-H |
| Fuel Consumption | 20.1 / 26.7 L/h (@75% / @100%) |
| Fuel Efficiency | 208 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 1900×890×1310 / 2580×1030×1500 mm |
| Weight (Open / Silent) | 1300 / 1800 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P150D5/S (120kW) · R-P180D5/S (144kW) · R-P200D5/S (160kW) · R-P230D5/S (184kW) · R-P250D5/S (200kW) · R-P300D5/S (240kW) · R-P350D5/S (280kW) — 1106A and 1506A families spanning the 100–350kW range
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
20.1 L/h
100% Load
26.7 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$20.1/hr | 100% load costs ~$26.7/hr
🛢️ Maintenance Quick Reference
Oil Capacity
8L
SAE 15W-40 CH-4
Coolant Capacity
13L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins 480kW Diesel Generator
Perkins 2800 Series · 50Hz · Model: R-P600D5/S
| Standby Power | 528 kW / 660 kVA |
| Prime Power | 480 kW / 600 kVA |
| Engine Model | Perkins 2806C-E18TAG1A |
| Alternator | Stamford S5L1D-E4 / Leroy-Somer TAL-A473-D |
| Fuel Consumption | 89.6 / 119.4 L/h (@75% / @100%) |
| Fuel Efficiency | 209 g/kW·h (ISO 3046-1) |
| Sound Level | ≤75 dB(A) at 7m |
| Dimensions (Open / Silent) | 3400×1120×2050 / 5030×1830×2050 mm |
| Weight (Open / Silent) | 3450 / 3900 kg |
| Price (Indicative) | Request Quote → |
Also covers: R-P400D5/S (320kW) through R-P2250D5/S (1800kW) — 2206C, 2506C, 2806A/E, 4006, 4008, and 4012 engine families. See the power range table above for all 17 models in this bracket.
💰 Operating Cost Estimate
Multiply fuel consumption by your local diesel price:
75% Load
89.6 L/h
100% Load
119.4 L/h
Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$89.6/hr | 100% load costs ~$119.4/hr
🛢️ Maintenance Quick Reference
Oil Capacity
40L
SAE 15W-40 CH-4
Coolant Capacity
52L
50:50 EG + distilled H₂O
See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.
Perkins Generator — Technical Data
Fuel Consumption
Most fuel-efficient · 2506C-E15TAG2 @ 400kW / 2806A-E18TAG2 @ 520kW
Actual consumption @75% load (sample)
10kW
108kW
480kW
Measured per ISO 3046-1 at 75% load. Actual varies ±5% with ambient conditions and load profile. Perkins mechanical injection engines are tolerant of varying fuel quality — a key advantage in developing markets.
Engineering & Configuration
H&C integrates Perkins engines from the 400 Series (7kW) to the 4000 Series (1,800kW) as a factory-direct manufacturer. Perkins engines built in China typically ship in 4–6 weeks; the 2000 Series (USA) and 4000 Series (India) depend on engine stock availability in China. Tell us your kW requirement — we will recommend a matching engine and alternator pair.
Standards & Compliance
Factory Load Test (ISO 8528)
Stepped load bank test on every unit. Reports available upon request.
Factory Warranty: 12 months / 1,000 hours — full Perkins factory warranty. Extended plans available upon request.
Frequently Asked Questions — Perkins Generators
How much does a Perkins diesel generator cost?
What is the fuel consumption of a Perkins generator?
Which Perkins engine series is right for my application?
What is the delivery time for a Perkins generator set?
Also available: Cummins · MTU · Mitsubishi