Perkins Diesel Generator Sets 7–1800kW

Factory-direct Perkins generators 7–1800kW. R-P series with genuine Perkins 400, 1100, 1200, 1500, 2200, 2500, 2800, and 4000 series engines. ISO 8528 certified. 50Hz. Backed by Perkins' worldwide service network.

VIEW POWER RANGE ↓ GET A QUOTE →

Why Choose Perkins Diesel Generators?

Perkins Engines Company Limited, headquartered in Peterborough, UK, is a subsidiary of Caterpillar Inc. with manufacturing facilities in China, India, the USA and the UK — a global footprint that gives buyers with engine-origin restrictions an extra choice. Perkins engines power generator sets from 7kW to 1,800kW.

H&C integrates the complete Perkins R-P series into our generator sets: from the compact 400 Series (7kW) to the industrial 4000 Series (1,800kW). Every genset is paired with a Stamford or Leroy-Somer alternator and Deep Sea / ComAp controller — assembled and load-tested at our manufacturing facility in Jiangsu, China per ISO 8528 standards.

For buyers, Perkins is engineered for low lifetime maintenance: the 2000 Series is built in the same factory as Caterpillar, and engines across families share common components with long service intervals. The 1100 Series uses mechanical injection with a 500-hour service interval — fast on-site servicing, less labour, and less downtime.

🌍

Global Manufacturing Footprint

Engines built in China, India, the USA and the UK — an extra choice for buyers whose project requires a specific engine origin.

🔩

Proven Reliability

The 2000 Series is built in the same factory as Caterpillar, backed by Perkins’ worldwide after-sales network.

🛠️

Simple Maintenance, Less Downtime

Single-side service, common components across engine families, and long intervals — the 1100 Series uses mechanical injection with a 500-hour service interval.

Perkins Generator Power Range

R-P series — 38 models covering 7–1800kW prime power. 50Hz / 400V / 0.8PF. Includes fuel consumption data. Click Details → for full specifications and application guidance.

Model Standby
kW / kVA
Prime
kW / kVA
Engine Model Fuel L/h
@75% / @100%
View
R-P9D5/S 7 / 9 7 / 9 403D-11G 1.6 / 2.1 Details →
R-P13D5/S 11 / 13 10 / 12 403D-15G 2.4 / 3.1 Details →
R-P15D5/S 13 / 16 12 / 15 403A-15G2 2.7 / 3.5 Details →
R-P20D5/S 17 / 22 16 / 20 404D-22G 3.6 / 4.8 Details →
R-P25D5/S 22 / 27 20 / 25 404D-22TG 4.2 / 5.6 Details →
R-P30D5/S 26 / 33 24 / 30 1103A-33G 5.1 / 6.8 Details →
R-P45D5/S 39 / 49 36 / 45 1103A-33TG1 6.8 / 9.0 Details →
R-P60D5/S 52 / 66 48 / 60 1103A-33TG2 9.1 / 12.2 Details →
R-P65D5/S 57 / 71 52 / 65 1104A-44TG1 9.8 / 13.1 Details →
R-P80D5/S 70 / 88 64 / 80 1104A-44TG2 11.9 / 15.8 Details →
R-P100D5/S 88 / 110 80 / 100 1104C-44TAG2 15.3 / 20.4 Details →
R-P135D5/S 118 / 148 108 / 135 1106A-70TG1 20.1 / 26.7 Details →
R-P150D5/S 132 / 165 120 / 150 1106A-70TAG2 21.6 / 28.9 Details →
R-P180D5/S 158 / 198 144 / 180 1106A-70TAG3 26.1 / 34.8 Details →
R-P200D5/S 176 / 220 160 / 200 1106A-70TAG4 29.0 / 38.7 Details →
R-P200D5/S 176 / 220 160 / 200 1206A-E70TTAG1 29.6 / 39.4 Details →
R-P230D5/S 202 / 253 184 / 230 1206A-E70TTAG2 35.0 / 46.7 Details →
R-P250D5/S 220 / 275 200 / 250 1206A-E70TTAG3 36.8 / 49.0 Details →
R-P300D5/S 264 / 330 240 / 300 1506A-E88TAG5 42.2 / 56.3 Details →
R-P350D5/S 308 / 385 280 / 350 2206C-E13TAG2 51.8 / 69.0 Details →
R-P400D5/S 352 / 440 320 / 400 2206C-E13TAG3 56.6 / 75.4 Details →
R-P450D5/S 396 / 495 360 / 450 2506C-E15TAG1 66.9 / 89.1 Details →
R-P500D5/S 440 / 550 400 / 500 2506C-E15TAG2 70.0 / 93.3 Details →
R-P600D5/S 528 / 660 480 / 600 2806C-E18TAG1A 89.6 / 119.4 Details →
R-P650D5/S 572 / 715 520 / 650 2806A-E18TAG2 95.6 / 127.5 Details →
R-P700D5/S 616 / 770 560 / 700 2806A-E18TTAG4 108.0 / 144.0 Details →
R-P750D5/S 660 / 825 600 / 750 2806A-E18TTAG5 113.0 / 150.7 Details →
R-P750D5/S 660 / 825 600 / 750 4006-23TAG2A 115.7 / 154.3 Details →
R-P800D5/S 704 / 880 640 / 800 4006-23TAG3A 115.4 / 153.9 Details →
R-P900D5/S 792 / 990 720 / 900 4008TAG1A 129.9 / 173.1 Details →
R-P1000D5/S 880 / 1100 800 / 1000 4008TAG2 150.0 / 200.0 Details →
R-P1125D5/S 990 / 1237 900 / 1125 4008-30TAG3 163.1 / 217.5 Details →
R-P1250D5/S 1100 / 1375 1000 / 1250 4012-46TWG2A 183.0 / 244.0 Details →
R-P1500D5/S 1320 / 1650 1200 / 1500 4012-46TAG2A 220.7 / 294.3 Details →
R-P1650D5/S 1452 / 1815 1320 / 1650 4012-46TAG3A 248.7 / 331.6 Details →
R-P1875D5/S 1650 / 2062 1500 / 1875 4016TAG1A 282.6 / 376.8 Details →
R-P2000D5/S 1760 / 2200 1600 / 2000 4016TAG2A 285.7 / 381.0 Details →
R-P2250D5/S 1980 / 2500 1800 / 2250 4016-61TRG3 334.3 / 445.7 Details →

Perkins Generator Specifications by Power Rating

Detailed specs and application guidance for 8 popular Perkins generator power ratings (10–480kW). Covers genuine Perkins 400, 1100, and 2800 series engines. 50Hz. Find every available model in the complete power range table above.

📋 Buying & Service Guides

Plan your purchase and keep your generator running at peak performance with our complete, brand-independent guides.

Diesel Generator Buying Guide → Diesel Generator Maintenance Schedule →

Perkins 10kW Diesel Generator

Perkins 400 Series · 50Hz · Model: R-P13D5/S

Standby Power11 kW / 13.8 kVA
Prime Power10 kW / 12.5 kVA
Engine ModelPerkins 403D-15G
AlternatorStamford S0L1-L1 / Leroy-Somer TAL-A40-C
Fuel Consumption2.4 / 3.1 L/h (@75% / @100%)
Fuel Efficiency264 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1160×780×1170 / 1830×750×1090 mm
Weight (Open / Silent)700 / 1050 kg
Price (Indicative) Request Quote →

Also covers: R-P9D5/S (7kW) · R-P15D5/S (12kW) — 403 family compact engines for light commercial backup

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

2.4 L/h

100% Load

3.1 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$2.4/hr | 100% load costs ~$3.1/hr

🛢️ Maintenance Quick Reference

Oil Capacity

6L

SAE 15W-40 CH-4

Coolant Capacity

5L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 16kW Diesel Generator

Perkins 400 Series · 50Hz · Model: R-P20D5/S

Standby Power17.6 kW / 22 kVA
Prime Power16 kW / 20 kVA
Engine ModelPerkins 404D-22G
AlternatorStamford S0L2-G1 / Leroy-Somer TAL-A40-F
Fuel Consumption3.6 / 4.8 L/h (@75% / @100%)
Fuel Efficiency250 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1160×780×1170 / 1830×750×1090 mm
Weight (Open / Silent)800 / 1120 kg
Price (Indicative) Request Quote →

Also covers: R-P25D5/S (20kW) — 404D-22TG turbocharged variant for higher output

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

3.6 L/h

100% Load

4.8 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$3.6/hr | 100% load costs ~$4.8/hr

🛢️ Maintenance Quick Reference

Oil Capacity

6L

SAE 15W-40 CH-4

Coolant Capacity

6L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 26kW Diesel Generator

Perkins 1100 Series · 50Hz · Model: R-P30D5/S

Standby Power26.4 kW / 33 kVA
Prime Power24 kW / 30 kVA
Engine ModelPerkins 1103A-33G
AlternatorStamford S0L2-P1 / Leroy-Somer TAL-A42-C
Fuel Consumption5.1 / 6.8 L/h (@75% / @100%)
Fuel Efficiency237 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1160×780×1170 / 2030×890×1105 mm
Weight (Open / Silent)840 / 1160 kg
Price (Indicative) Request Quote →

Also covers: R-P45D5/S (36kW) — 1103A-33TG1, the first turbocharged model in the 1100 Series

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

5.1 L/h

100% Load

6.8 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$5.1/hr | 100% load costs ~$6.8/hr

🛢️ Maintenance Quick Reference

Oil Capacity

8L

SAE 15W-40 CH-4

Coolant Capacity

8L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 57kW Diesel Generator

Perkins 1100 Series · 50Hz · Model: R-P65D5/S

Standby Power57.2 kW / 71.5 kVA
Prime Power52 kW / 65 kVA
Engine ModelPerkins 1104A-44TG1
AlternatorStamford UCI224F / Leroy-Somer TAL-A42-H
Fuel Consumption9.8 / 13.1 L/h (@75% / @100%)
Fuel Efficiency212 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1680×825×1230 / 2480×1030×1315 mm
Weight (Open / Silent)1140 / 1560 kg
Price (Indicative) Request Quote →

Also covers: R-P60D5/S (48kW) — 1103A-33TG2, the final 1103A evolution before the 1104A platform

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

9.8 L/h

100% Load

13.1 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$9.8/hr | 100% load costs ~$13.1/hr

🛢️ Maintenance Quick Reference

Oil Capacity

8L

SAE 15W-40 CH-4

Coolant Capacity

10L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 70kW Diesel Generator

Perkins 1100 Series · 50Hz · Model: R-P80D5/S

Standby Power70.4 kW / 88 kVA
Prime Power64 kW / 80 kVA
Engine ModelPerkins 1104A-44TG2
AlternatorStamford UCI224G / Leroy-Somer TAL-A44-C
Fuel Consumption11.9 / 15.9 L/h (@75% / @100%)
Fuel Efficiency208 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1860×855×1250 / 2580×1030×1500 mm
Weight (Open / Silent)1150 / 1600 kg
Price (Indicative) Request Quote →

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

11.9 L/h

100% Load

15.9 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$11.9/hr | 100% load costs ~$15.9/hr

🛢️ Maintenance Quick Reference

Oil Capacity

8L

SAE 15W-40 CH-4

Coolant Capacity

13L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 80kW Diesel Generator

Perkins 1100 Series · 50Hz · Model: R-P100D5/S

Standby Power88 kW / 110 kVA
Prime Power80 kW / 100 kVA
Engine ModelPerkins 1104C-44TAG2
AlternatorStamford UCI274C / Leroy-Somer TAL-A44-D
Fuel Consumption15.3 / 20.4 L/h (@75% / @100%)
Fuel Efficiency214 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1860×855×1250 / 2580×1030×1500 mm
Weight (Open / Silent)1200 / 1700 kg
Price (Indicative) Request Quote →

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

15.3 L/h

100% Load

20.4 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$15.3/hr | 100% load costs ~$20.4/hr

🛢️ Maintenance Quick Reference

Oil Capacity

8L

SAE 15W-40 CH-4

Coolant Capacity

13L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 108kW Diesel Generator

Perkins 1100 Series · 50Hz · Model: R-P135D5/S

Standby Power118.8 kW / 148.5 kVA
Prime Power108 kW / 135 kVA
Engine ModelPerkins 1106A-70TG1
AlternatorStamford UCI274E / Leroy-Somer TAL-A44-H
Fuel Consumption20.1 / 26.7 L/h (@75% / @100%)
Fuel Efficiency208 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)1900×890×1310 / 2580×1030×1500 mm
Weight (Open / Silent)1300 / 1800 kg
Price (Indicative) Request Quote →

Also covers: R-P150D5/S (120kW) · R-P180D5/S (144kW) · R-P200D5/S (160kW) · R-P230D5/S (184kW) · R-P250D5/S (200kW) · R-P300D5/S (240kW) · R-P350D5/S (280kW) — 1106A and 1506A families spanning the 100–350kW range

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

20.1 L/h

100% Load

26.7 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$20.1/hr | 100% load costs ~$26.7/hr

🛢️ Maintenance Quick Reference

Oil Capacity

8L

SAE 15W-40 CH-4

Coolant Capacity

13L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins 480kW Diesel Generator

Perkins 2800 Series · 50Hz · Model: R-P600D5/S

Standby Power528 kW / 660 kVA
Prime Power480 kW / 600 kVA
Engine ModelPerkins 2806C-E18TAG1A
AlternatorStamford S5L1D-E4 / Leroy-Somer TAL-A473-D
Fuel Consumption89.6 / 119.4 L/h (@75% / @100%)
Fuel Efficiency209 g/kW·h (ISO 3046-1)
Sound Level≤75 dB(A) at 7m
Dimensions (Open / Silent)3400×1120×2050 / 5030×1830×2050 mm
Weight (Open / Silent)3450 / 3900 kg
Price (Indicative) Request Quote →

Also covers: R-P400D5/S (320kW) through R-P2250D5/S (1800kW) — 2206C, 2506C, 2806A/E, 4006, 4008, and 4012 engine families. See the power range table above for all 17 models in this bracket.

💰 Operating Cost Estimate

Multiply fuel consumption by your local diesel price:

75% Load

89.6 L/h

100% Load

119.4 L/h

Operating cost = L/h × local diesel price (check your regional rate)
Example: at $1.0/L → 75% load costs ~$89.6/hr | 100% load costs ~$119.4/hr

🛢️ Maintenance Quick Reference

Oil Capacity

40L

SAE 15W-40 CH-4

Coolant Capacity

52L

50:50 EG + distilled H₂O

See Maintenance Schedule for full service intervals and Buying Guide for pre-order guidance.

Perkins Generator — Technical Data

Fuel Consumption

196 g/kW·h

Most fuel-efficient · 2506C-E15TAG2 @ 400kW / 2806A-E18TAG2 @ 520kW

400 Series (403–404D) 250–264 g/kW·h 7–20kW
1100 Series (1103–1106A) 197–237 g/kW·h 24–280kW
2800/4000 Series (2806–4016) 196–216 g/kW·h 320–1,800kW

Actual consumption @75% load (sample)

2.4 L/h
10kW
20.1 L/h
108kW
89.6 L/h
480kW

Measured per ISO 3046-1 at 75% load. Actual varies ±5% with ambient conditions and load profile. Perkins mechanical injection engines are tolerant of varying fuel quality — a key advantage in developing markets.

Engineering & Configuration

H&C integrates Perkins engines from the 400 Series (7kW) to the 4000 Series (1,800kW) as a factory-direct manufacturer. Perkins engines built in China typically ship in 4–6 weeks; the 2000 Series (USA) and 4000 Series (India) depend on engine stock availability in China. Tell us your kW requirement — we will recommend a matching engine and alternator pair.

Standards & Compliance

Factory Load Test (ISO 8528)

0% → 25% → 50% → 75% → 100% → 110%

Stepped load bank test on every unit. Reports available upon request.

CE ISO 9001 ISO 14001 ISO 8528-5

Factory Warranty: 12 months / 1,000 hours — full Perkins factory warranty. Extended plans available upon request.

Frequently Asked Questions — Perkins Generators

How much does a Perkins diesel generator cost?+
A Perkins diesel generator is priced mainly by its power rating and the engine series behind it. H&C builds Perkins sets from 7kW to 1,800kW: the 400 Series (403D/404D) covers 7–20kW, the 1100 Series (1103/1104/1106A) covers 24–280kW, and the 2800/4000 Series (2806–4016) covers 320–1,800kW. Configuration also moves the price — open skid, soundproof canopy or containerized enclosure, Stamford or Leroy-Somer alternator, Deep Sea, ComAp or SmartGen controller, and options such as ATS. Tell us the required kW, voltage and destination country and we will quote the matching Perkins series within 24 hours.
What is the fuel consumption of a Perkins generator?+
Perkins generator fuel consumption is 196–264 g/kW·h depending on engine series. The 400 Series (403–404D) uses 250–264 g/kW·h, the 1100 Series (1103–1106A) 197–237 g/kW·h, and the 2800/4000 Series (2806–4016) 196–216 g/kW·h; the most efficient models are the 2506C-E15TAG2 at 400kW and the 2806A-E18TAG2 at 520kW, both at 196 g/kW·h. In litres, a Perkins set consumes about 2.4 L/h at 10kW, 20.1 L/h at 108kW and 89.6 L/h at 480kW at 75% load. Figures are measured to ISO 3046-1 and vary about ±5% with ambient conditions and load profile; the power range table above lists L/h at 75% and 100% for every model.
Which Perkins engine series is right for my application?+
Choose the Perkins series by power rating and duty cycle. The 400 Series (403D/404D, 7–20kW) is a compact 3-4 cylinder for light commercial and residential standby. The 1100 Series (1103/1104/1106A, 24–280kW) is the most widely used platform for industrial standby and light prime power, with mechanical injection and a 500-hour service interval. The 1200/1500 Series covers commercial prime power and the 2200/2500 Series heavy-duty standby. The 2800/4000 Series (2806–4016, 320–1,800kW) uses V8, V12 and V16 engines for large-scale prime and baseload duty. H&C supplies both Perkins and Cummins engines — send your kW, load profile and country and we will recommend which fits.
What is the delivery time for a Perkins generator set?+
The delivery time depends on the engine model. Perkins engines built in China typically ship in 4–6 weeks after order confirmation. For the 2000 Series manufactured in the USA and the 4000 Series manufactured in India, the lead time depends on the engine's stock availability in China. Every set is assembled and load-tested at our manufacturing facility in Jiangsu, China to ISO 8528 before shipment. Send your engine model and required quantity and we will confirm the current engine lead time with Perkins.
GET PERKINS QUOTE

Also available: Cummins · MTU · Mitsubishi